Модуль дискретного вывода для систем безопасности, 4 канала 24 В/0,5 А пост. тока
|
Наименование
|
Модуль дискретных выходов SM 022, DO 4 output, current 0,5A, safety |
|
Тип
|
022-1SD00 |
|
Габаритные размеры, В х Ш х Г, мм
|
12.9 mm x 109 mm x 76.5 mm |
|
Температура окружающей среды
|
0 °C .. 60 °C |
|
Количество выходов
|
4 |
|
Тип выходного сигнала
|
24VDC |
![]() |
|
Status indication
![]() |
RUN | MF | Description |
| green | red |
|
|
| ● | ○ | Bus communication is OK Module status is OK |
|
| ● | ● |
Bus communication is OK |
|
| ○ | ● |
Bus communication is not possible |
|
| ○ | ○ | Error at bus power supply | |
| B | B |
Error in configuration |
|
| on: ● | off: ○ | blinking with 0.5Hz: B | |||
| LED | Color | Description | |
| PS | green | ● |
PROFIsafe communication in data exchange |
| BB | Safety parametrization expected | ||
| B | Error - acknowledgement expected | ||
| ○ | Module initialization is running | ||
| ERR | red | ● | Permanent fail-safe condition |
| C | Blink code | ||
| ERR2 | yellow | C | Blink code |
| B | Requesting fail-safe state | ||
| DO x | green | ● | Digital input is triggered |
|
on: ● | off: ○ | blinking with 0.5Hz: B | blinking with 2Hz: BB | Blink code: C |
|||
Pin assignment
| PM - Power module | Pos. | Function |
Type |
Description | |
![]() |
1 | DO 0 | O | Digital output DO 0 | |
| 2 | 0V | O |
GND for actuator |
||
| 3 | DO 2 | O |
Digital output DO 2 |
||
| 4 | 0V | O | GND for actuator | ||
| 5 | DO 1 | O | Digital output DO 1 | ||
| 6 | 0V | O |
GND for actuator |
||
| 7 | DO 3 | O |
Digital output DO 3 |
||
| 8 | 0V | O | GND for actuator |
O: Output
Order no. |
022-1SD00 |
| Type | SM 022 |
| Module ID | 0C81 1E00 |
General information |
|
| Note | - |
| Features | 4 outputs Safety Output current 0.5 A |
Current consumption/power loss |
|
| Current consumption from backplane bus | 75 mA |
| Power loss | 1 W |
Technical data digital outputs |
|
| Number of outputs | 4 |
| Cable length, shielded | 1000 m |
| Cable length, unshielded | 600 m |
| Rated load voltage | DC 20.4...28.8 V |
| Current consumption from load voltage L+ (without load) | 15 mA |
| Total current per group, horizontal configuration, 40°C | 2 A |
| Total current per group, horizontal configuration, 60°C | - |
| Total current per group, vertical configuration | - |
| Output current at signal "1", rated value | 0.5 A |
| Output delay of "0" to "1" | 100 µs |
| Output delay of "1" to "0" | 175 µs |
| Minimum load current | - |
| Lamp load | 5 W |
| Parallel switching of outputs for redundant control of a load | not possible |
| Parallel switching of outputs for increased power | not possible |
| Actuation of digital input | ![]() |
| Switching frequency with resistive load | max. 50 Hz |
| Switching frequency with inductive load | max. 0.5 Hz |
| Switching frequency on lamp load | max. 10 Hz |
| Internal limitation of inductive shut-off voltage | L+ (-45 V) |
| Short-circuit protection of output | yes, electronic |
| Trigger level | 1.7 A |
| Number of operating cycle of relay outputs | - |
| Switching capacity of contacts | - |
| Output data size | 4 Bit |
Status information, alarms, diagnostics |
|
| Status display | green LED per channel |
| Interrupts | yes, parameterizable |
| Process alarm | no |
| Diagnostic interrupt | yes, parameterizable |
| Diagnostic functions | yes, parameterizable |
| Diagnostics information read-out | possible |
| Supply voltage display | green LED |
| Group error display | red SF LED |
| Channel error display | red ERR-LED and yellow ER2-LED |
Isolation |
|
| Between channels | - |
| Between channels of groups to | - |
| Between channels and backplane bus | ![]() |
| Insulation tested with | DC 500 V |
PWM data |
|
| PWM channels | - |
| PWM time basis | - |
| Period length | - |
| Minimum pulse width | - |
| PtP communication | - |
Safety |
|
| Safety protocol | PROFIsafe V2 |
| Safety requirements | SIL CL 3, PL e, Kat 4 |
| Secure user address | 1 - 4095 |
| Watchdog | parameterizable 10ms - 1s |
| Two channels | Each 2 of 4 outputs switchable |
| Test pulse length | parameterizable 500µs - 10ms |
| Circuit monitoring | ![]() |
Datasizes |
|
| Input bytes | 5 |
| Output bytes | 5 |
| Parameter bytes | 44 |
| Diagnostic bytes | 20 |
Housing |
|
| Material | PC / PPE GF10 |
| Mounting | Profile rail 35 mm |
Mechanical data |
|
| Dimensions (WxHxD) | 12.9 mm x 109 mm x 76.5 mm |
| Weight | 60 g |
Environmental conditions |
|
| Operating temperature | 0 °C to 60 °C |
| Storage temperature | -25 °C to 70 °C |
Certifications |
|
| UL508 certification | in preparation |
| Order no. | Name/Description | |
|---|---|---|
|
021-1BB00 |
SM 021 - Digital input 2 inputs |
|
|
021-1BB10 |
SM 021 - Digital input 2 fast inputs Input filter time delay parameterizable 2 µs...4 ms |
|
|
021-1BB50 |
SM 021 - Digital input 2 inputs Active low input |
|
|
021-1BB70 |
SM 021 - Digital input 2 inputs Time stamp |
|
|
021-1BD00 |
SM 021 - Digital input 4 inputs |
|
|
021-1BD10 |
SM 021 - Digital input 4 fast inputs Input filter time delay parameterizable 2 µs...4 ms |
|
|
021-1BD40 |
SM 021 - Digital input 4 inputs Connect 2/3-wire |
|
|
021-1BD50 |
SM 021 - Digital input 4 inputs Active low input |
|
|
021-1BD70 |
SM 021 - Digital input 4 inputs Time stamp |
|
|
021-1BF00 |
SM 021 - Digital input 8 inputs |
|
|
021-1BF01 |
SM 021 - Digital input 8 Inputs, 0.5ms |
|
|
021-1BF50 |
SM 021 - Digital input 8 inputs Active low input |
|
|
021-1DF00 |
SM 021 - Digital input 8 inputs diagnosis of wiring errors |
|
|
021-1SD00 |
SM 021 - Digital input 4 inputs Safety |
|
|
022-1BB00 |
SM 022 - Digital output 2 outputs Output current 0.5 A |
|
|
022-1BB20 |
SM 022 - Digital output 2 outputs Output current 2 A |
|
|
022-1BB50 |
SM 022 - Digital output 2 Low-Side outputs Output current 0.5 A |
|
|
022-1BB70 |
SM 022 - Digital output 2 outputs Time stamp Output current 0.5 A |
|
|
022-1BB90 |
SM 022 - Digital output 2 outputs PWM |
|
|
022-1BD00 |
SM 022 - Digital output 4 outputs Output current 0.5 A |
|
|
022-1BD20 |
SM 022 - Digital output 4 outputs Output current 2 A |
|
|
022-1BD50 |
SM 022 - Digital output 4 Low-Side outputs Output current 0.5 A |
|
|
022-1BD70 |
SM 022 - Digital output 4 outputs Time stamp Output current 0.5 A |
|
|
022-1BF00 |
SM 022 - Digital output 8 outputs Output current 0.5 A |
|
|
022-1BF50 |
SM 022 - Digital output 8 Low-Side outputs Output current 0.5 A |
|
|
022-1DF00 |
SM 022 - Digital output 8 outputs Output current 0.5 A diagnosis of wiríng errors |
|
|
022-1HB10 |
SM 022 - Digital output 2 relay outputs DC 30 V/ AC 230 V Output current 3 A |
|
|
022-1HD10 |
SM 022 - Digital output 4 relay outputs DC 30 V / AC 230 V Output current 1.8 A |
|
|
022-1SD00 |
SM 022 - Digital output 4 outputs Safety Output current 0.5 A |
|
Изделие: 022-1BD00
4 канала 24 В/0,5 А пост. тока
Изделие: 022-1HB10
2 реле, напряжение нагрузки 30 В пост. тока/ 230 В перем тока, коммутируемый ток до 3 А